(SS) p-Terphenyl-d14
CAS # 1718-51-0
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
244.3900
Formula
C
18
D
14
Data above sourced from:
ChemSpider
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
p-Terphenyl-d14; [2H14]Terphenyl; p-Terphényl-d14; p-Terfenile-d14
Related Products
Base Neutral Surrogate Mix (4/89 SOW), 5000 µg/mL, Methylene Chloride, 1 mL/ampul
Base Neutral Surrogate Mix (3/90 SOW), 1000 µg/mL, Methylene Chloride, 1 mL/ampul
Revised B/N Surrogate Mix, 5000 µg/mL, Methylene Chloride, 1 mL/ampul, 15-pk.
Base Neutral Surrogate Mix (4/89 SOW), 1000 µg/mL, Methylene Chloride, 1 mL/ampul
Base Neutral Surrogate Mix (3/90 SOW), 5000 µg/mL, Methylene Chloride, 5 mL/ampul
Revised B/N Surrogate Mix, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
Base Neutral Surrogate Mix (3/90 SOW), 5000 µg/mL, Methylene Chloride, 1 mL/ampul
Revised B/N Surrogate Mix, 5000 µg/mL, Methylene Chloride, 1 mL/ampul
Base Neutral Surrogate Mix (4/89 SOW), 1000 µg/mL, Methylene Chloride, 1 mL/ampul, 15-pk.
Base Neutral Surrogate Mix (4/89 SOW), 5000 µg/mL, Methylene Chloride, 1 mL/ampul, 15-pk.
Base Neutral Surrogate Mix (4/89 SOW), 5000 µg/mL, Methylene Chloride, 5 mL/ampul
Base Neutral Surrogate Mix (4/89 SOW), 1000 µg/mL, Methylene Chloride, 1 mL/ampul, 25-pk.
Revised B/N Surrogate Mix, 5000 µg/mL, Methylene Chloride, 5 mL/ampul
CLP 04.1 BNA Surrogate Mix, Methylene Chloride, 1 mL/ampul
Base Neutral Surrogate Mix (4/89 SOW), 5000 µg/mL, Methylene Chloride, 10 mL/ampul
Method 525.2 Fortification Recovery Standard (p-Terphenyl-d14), 1000 µg/mL, Methylene Chloride, 1 mL/ampul
Application Chromatograms
Semivolatiles on Rxi-SVOCms
Semivolatiles Analysis on Rxi-SVOCms
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
16 Priority PAHs and Methylnaphthalenes on Rxi- 5Sil MS using the GC Accelerator Kit in a 208 V Oven
16 Priority PAHs and Methylnaphthalenes on Rxi-5Sil MS using the GC Accelerator Kit in a 120 V Oven
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Minnesota Dept. of Agriculture List 1 Pesticides on Rxi-1ms
Polycyclic Aromatic Hydrocarbons by EPA 610 on Rxi-5ms
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx-5MS